● 1: Standard parameters. In this mode, parameters in group b and S (S0, S2 and S3)
are visible.
● 2: Extended parameters. In this mode, parameters in group b, S and E (E0, E1, E2,
E3 and E4) are visible.
● 3: Advanced parameters. In this mode, parameters in group b, S, E and H (H0) are
visible.
● 4: Start-up mode. The parameters in this mode are not additional parameters, but
only quick links to the respective parameters. See the table below for details:
Function code
Name
[b0.21]
Carrier frequency
[b1.00]
First frequency setting source
[b1.02]
First RUN command source
[b1.04]
Digital set frequency
[b1.05]
Max. frequency
[b1.06]
Upper frequency
[b1.07]
Lowest frequency
[b1.10]
Direction control
[b1.20]
Acceleration time 1
[b1.21]
Deceleration time 1
[b1.22]
Acceleration / deceleration curve mode
[b1.30]
Starting mode
[b1.40]
Stopping mode
[S0.00]
V/F curve mode
[S2.00]
Rated motor frequency
[S2.01]
Rated motor rotation speed
[S2.02]
Rated motor power
[S2.03]
Rated motor voltage
[S2.04]
Rated motor current
Fig.8-1: Parameters in start-up mode
● Monitoring parameter group is always visible.
● User password protection will not affect the modification of [b0.02].
Bosch Rexroth AG
Parameter Settings
DOK-RCON03-EFC-3600***-IT01-EN-P
Rexroth Frequency Converter EFC 3600
54/235
Summary of Contents for Rexroth EFC 3600
Page 6: ...Bosch Rexroth AG DOK RCON03 EFC 3600 IT01 EN P Rexroth Frequency Converter EFC 3600 IV 235 ...
Page 232: ...230 235 ...
Page 236: ...Bosch Rexroth AG DOK RCON03 EFC 3600 IT01 EN P Rexroth Frequency Converter EFC 3600 234 235 ...
Page 237: ...Notes DOK RCON03 EFC 3600 IT01 EN P Rexroth Frequency Converter EFC 3600 Bosch Rexroth AG ...