Function
code
Name
Setting range
Min.
unit
Factory
default Attribute
b1.17
Second RUN
command
source
0: Inputting commands with
panel
1: Inputting commands via
external terminals
2: Inputting commands via
communication
1
1
STOP
b1.18
~
b1.19
Reserved
–
–
–
–
Acceleration/deceleration control
Function
code
Name
Setting range
Min.
unit
Factory
default Attribute
b1.20 Acceleration time 1
0.1 ~ 6000.0s
0.1s
5.0s
RUN/
STOP
b1.21 Deceleration time 1
0.1 ~ 6000.0s
0.1s
5.0s
RUN/
STOP
b1.22 Acceleration / deceleration
curve mode
0: Linear
1: S-curve
1
0
STOP
b1.23
S curve starting phase
proportion
0.0 % ~ 40.0 %
0.1 %
20.0 %
STOP
b1.24
S curve stopping phase
proportion
0.0 % ~ 40.0 %
0.1 %
20.0 %
STOP
b1.25
~
b1.29
Reserved
–
–
–
–