Additional running control
Function
code
Name
Setting range
Min.
unit
Factory
default Attribute
S3.30 Forward and reverse ro‐
tation dead zone time
0.0 ~ 60.0s
0.1s
4.0s
STOP
S3.32 UP/DOWN set velocity 0.10 ~ 100.00 Hz/s
0.01
Hz/s 1.00 Hz/s
RUN/
STOP
S3.33 UP/DOWN terminals ini‐
tial frequency
[b1.07] ~ [b1.06]
0.01 Hz 0.00 Hz
RUN/
STOP
S3.34 Fan control
0: Automatically con‐
trolled
1: Always on
1
0
RUN/
STOP
S3.35 Stopping with Stop key
0: Only valid for con‐
trol with keyboard
1: Valid for all con‐
trol means
1
1
RUN/
STOP
17.2.7
Group E0: Input Terminals
Multi-function digital input terminals
Function
code
Name
Setting range
Min.
unit
Factory
default Attribute
E0.00 2-wire/3-wire
running control
0: Forward/stop, reverse/stop
1: Forward/reverse, run/stop
2: 3-wire control
1
0
STOP
E0.01 X1 terminal
0 ~ 28
1
0
STOP
E0.02 X2 terminal
1
0
STOP
E0.03 X3 terminal
1
0
STOP
E0.04 X4 terminal
1
0
STOP
E0.05 X5 terminal
1
0
STOP
E0.06
~
E0.09
Reserved
–
–
–
–
Setting range of [E0.01] ~ [E0.05] is as below:
0: No action (multiple choices allowed)
1: Multi-speed control terminal 1
Bosch Rexroth AG
Appendix
DOK-RCON03-EFC-3600***-IT01-EN-P
Rexroth Frequency Converter EFC 3600
208/235
Summary of Contents for Rexroth EFC 3600
Page 6: ...Bosch Rexroth AG DOK RCON03 EFC 3600 IT01 EN P Rexroth Frequency Converter EFC 3600 IV 235 ...
Page 232: ...230 235 ...
Page 236: ...Bosch Rexroth AG DOK RCON03 EFC 3600 IT01 EN P Rexroth Frequency Converter EFC 3600 234 235 ...
Page 237: ...Notes DOK RCON03 EFC 3600 IT01 EN P Rexroth Frequency Converter EFC 3600 Bosch Rexroth AG ...