D9412GV2/D7412GV2 |
Program Entry Guide | 2.0
GV2MAIN
EN
| 45
Bosch Security Systems | 5/05 | F001U003636B
Parameter Setup Requirement:
The Early Ambush timer can be started and stopped
only by pass codes with the L## Passcode Disarm
authority.
To avoid unintended results for the end
user of the system:
•
When a keypad is assigned to an area
that has the Early Ambush feature
enabled, set the
CC# Scope
value to
Area Wide.
•
If an area has
A# Two Man Rule
set to
Yes
, do not set
A# Early Ambush
to
Yes
.
During an alarm, after the first pass code is entered,
the Early Ambush timer still begins. A Cancel Report
might be generated, depending upon the bell time, and
the keypad displays
Alarm Silenced
normally. If
the second valid disarm pass code is entered, the
keypads indicate that the second pass code is valid.
Refer to the
Secondary Ambush Code
prompt on
page 132 for information about the unique behavior of
the two pass codes.
2.10 Keypad (Command Center)
This programming module contains three
programming categories: Cmd Cntr Assignment, Area
Text, and Custom Function.
2.10.1 Keypad (Command Center) Assignment
This programming category assigns a keypad to an
area and determines if the keypad is supervised. The
keypads are connected to the control panel using a
two-wire serial data interface (SDI) bus.
This bus can support up to eight supervised keypads,
each with its own unique keypad address (CC) and
corresponding DIP switch address settings. If the
keypads are not supervised, you can install multiple
keypads with the same DIP switch address setting for
up to 32 unsupervised keypads.
Cmd Center
Default:
1
Selection:
1 to 8
DIP Switch Setting
SDI
CC#
Address
Number
1 2 3 4 5 6
1
1
ON ON ON ON -- ON
2
2
OFF ON ON ON -- ON
3 3
ON OFF ON ON
--
ON
4 4
OFF OFF ON ON
--
ON
5 5
ON ON OFF ON -- ON
6 6
OFF ON OFF ON -- ON
7 7
ON OFF OFF ON
--
ON
8 8
OFF OFF OFF ON
--
ON
Enter the keypad (CC) number for the SDI address you are programming. This number corresponds to the DIP
switch address settings shown.