D9412GV2/D7412GV2 |
Program Entry Guide | 5.0
RADXSKED
EN
| 99
Bosch Security Systems | 5/05 | F001U003636B
5.0 RADXSKED
5.1 Windows
Use this programming module to define the windows
for Opening and Closing and User Access.
5.1.1
Opening and Closing
Use these windows to set a schedule for disarming and
arming. The disarming and arming schedules have
several independent features:
•
Suppress normal Opening or Closing Reports
when
A# Disable O/C in Windows
is
programmed as
Yes
.
•
Generate a Fail to Open Report if the area is not
disarmed on schedule when
A# Fail To Open
is
programmed as
Yes
.
•
Provide a warning tone and a
PLEASE CLOSE
NOW
display at the keypad when it is time to arm
the area.
•
Generate a Fail to Close Report if the area is not
armed on schedule when
A# Fail To Close
is
programmed as
Yes
.
•
Automatically arm the area at the end of the
Closing Window when
A# Auto Close
is
programmed as
Yes
.
Opening and closing schedules can be set up
independently. For example, if you want to use
features provided only by Closing Windows, leave
times blank in the Opening Windows prompts and
program Closing Window times.
A worksheet is provided at the end of this section for
your convenience. Following the worksheet are
examples of programmming Opening and Closing
Windows for particular applications (refer to
Table 36
on page 105 through
Table 40
on page 106).
About the program record sheet:
A column labeled
Sked # is found in the
program record sheet provided
with the control panel. The numbers in that column
appear in D6500 and D6600 reports and local printer
reports when the window Begin Time executes.
Window selections 1 through 8 correspond with odd-
numbered Skeds 41 through 55 for Open Window and
correspond with even numbered Skeds 42 through 56
for Close Window. For example, when the Opening
Window for Window 1 executes, a Sked 41 Executed
event is generated. Refer to
Table 32
.
Table 32: Window Selections
Selection
Sked # Window
Sked #
Window
1
41
Open
42
Close
2 43
Open
44
Close
3
45
Open
46
Close
4 47
Open
48
Close
5
49
Open
50
Close
6 51
Open
52
Close
7
53
Open
54
Close
8 55
Open
56
Close
Window
Default:
1
Selection:
1 to 8
Enter the window number you want to program.
W# Sunday
Default:
No
Selection:
Yes or No
Yes
Activate this window on Sundays.
No
Do not activate this window on
Sundays.
This prompt and the next six day-of-the-week prompts
select the days of the week the Opening and Closing
windows are active.
Exceptions:
To prevent the windows from activating on certain
days of the year, program
Xept Holiday
as
Yes
, and
enable at least one Holiday Index. When
Xept
Holiday
is
Yes
, the window executes on the days of
the week programmed unless the Holiday Index
designates the date as a holiday.
If Opening and Closing Windows are only needed on
certain days of the year, do not program the windows
to execute on any days of the week. Instead, program
Xept Holiday
as
No
and select a Holiday Index with
the days of the year you want the window to be active.