L## View Memory
Default:
Refer to the program record sheet
Selection: Blank or E
Function No.
Function Name
Alternate Keystroke
9 View
Event
Memory
[COMMAND][4][0]
View all memory events that occurred since the last
time the system was armed for all areas within the
scope of the keypad in this area.
L## View Pt Status
Default:
Refer to the program record sheet
Selection:
Blank or E
Function No.
Function Name
Alternate Keystroke
10
View Point Status
(Menu function only)
View the current status of all points in the area to
which this keypad is assigned.
L## Walk Test
Default:
Refer to the program record sheet
Selection:
Blank or E
Function No.
Function Name
Alternate Keystroke
11 Walk
Test
[COMMAND][4][4]
Walk Test all Interior or Perimeter Controlled points
in the area to which this keypad is assigned.
The following features come with the Walk Test
Mode:
•
Battery powered control panel only. A Battery
Test runs during the whole test to ensure that the
battery capacity is capable of supporting the full
load of the control panel if AC fails.
-
This test includes two-second Bell Test when
the Walk Test starts.
-
The test ends when all points are tested or the
test times out after 20 minutes of no activity.
•
Local alarm annunciation and event printing; no
reports are sent to the central station receiver.
•
D1255 Keypad displays a sequential count, and
text after each point is activated and restored.
•
The keypad displays
ALL PTS TESTED
and an
All Points Tested Event is sent to the central
station receiver (if programmed) when the last
point is tested.
•
If enabled in Routing, Walk Start and Walk End
Reports are sent to the central station receiver at
the beginning and end of the test.
To Walk Test a Door point connected to a
D9210B Access Interface Module, open
the door without activating the door
sequence or allowing it to time out past the
extended shunt time.
L## Fire Test
Default:
Refer to the program record sheet
Selection: Blank or E
Function No.
Function Name
Alternate Keystroke
12 Fiire
Test
[COMMAND][5][8]
Fire Walk Test all 24-hour points in the area where
this keypad is assigned.
One person can perform a Fire Walk Test without
assistance. The following features come with the Fire
Test Mode:
•
Battery powered control panel only. A Battery
Test runs during the whole test to ensure that the
battery capacity is capable of supporting the full
load of the control panel if AC fails.
-
This test includes a 2-second Bell Test (Fire
Bell relay) for each Fire point that is tested.
-
The test ends when all points are tested or the
test times out after 20 minutes of no activity.
•
Local alarm annunciation and event printing; no
reports are sent without reporting to the central
station receiver.
•
Automatic smoke detectors reset for all Fire points
programmed with
P## Resettable
as
Yes
.
•
D1255 Keypad displays a sequential count and the
text for the point after each point is activated and
restored.
•
If enabled in Routing, Walk Start and Walk End
Reports are sent to the central station receiver at
the beginning and end of the test.
A# Verify Time
for Fire points that is
programmed with
Yes
for
P## Alarm
Verify
is ignored during the Fire Walk Test.