CIP5000 series storage
Hardware configuration | en
21
Bosch Security Systems B.V.
User manual
2019-10 | V01 | F.01U.380.030
Rails installed
and tightened
Brackets
3U 16-bay
enclosure hardware
Figure
5.3: Placing the enclosure hardware onto the rack rails
Screws and flange
nuts attach the
enclosure hardware
to the rack posts
Figure
5.4: Secure to rack
Handles mount
outside the rack post
Mounting rails mount
outside the rack post
Vertical rack post
Figure
5.5: System installed in rack
To install the enclosure hardware into a rack with the supplied rails:
1.
Check the fit of the rails in your rack system.
2.
Adjust the length of the rails as needed.
–
The rear half of the rail slides inside the front half. The rail halves are riveted
together, so no adjustment screws are needed.
–
The front-left and front-right rail ends are labeled.
–
Be sure the front rail support is on the bottom facing inward.
–
All rail ends, front and rear, attach at the outside of the rack posts.
–
The guide pins at the rail ends align with the holes in the rack posts.