56
en | Spare drives
CIP5000 series storage
2019-10 | V01 | F.01U.380.030
User manual
Bosch Security Systems B.V.
18
Spare drives
When a physical drive in a disk array fails, a spare drive with sufficient capacity is available
and the disk array begins to rebuild automatically with a spare drive.
In the tree view, click on the Spare Drive icon to view the list of spare drives, to create a new
spare drive, or to delete an existing spare drive. Click any spare drive in the list to learn about
the drive.
Spare drive information includes:
–
Spare Drive ID
–
Physical Drive ID
–
Spare Type
–
Revertible [Yes/No]
–
Operational Status
–
Spare Check Status
–
Physical Capacity
–
Configurable Capacity
–
Block Size
–
Drive Interface
–
Model
–
Location
–
Configuration Status
–
Serial Number
–
Firmware Version
18.1
Run spare check
Spare check verifies the operation status of your spare drive. In addition, you can schedule a
spare check.
To check the spare drive:
1.
Click the Spare Drives icon.
2.
Click the Spare Check tab.
3.
From the Physical Drives drop-down menu, select the spare drive you want to check. Or
select All to check all spare drives at the same time.
4.
Click the
Submit
button.
The result of the spare check displays under the spare check status in the Info tab. “Health”
means normal conditions.