50
en | Enclosures
CIP5000 series storage
2019-10 | V01 | F.01U.380.030
User manual
Bosch Security Systems B.V.
15
Enclosures
The Enclosures menu provides information about the individual components of the enclosure
and monitors its status. Click on a specific enclosure in the tree view or in the enclosures list
to display information or settings menu of this enclosure.
Locate the enclosure
To locate an enclosure in the list, click the
Locate
button. The LED indicators on the front
panel of the enclosure flash for one minute.
15.1
Enclosure information
The enclosure information read-only display menu provides key real-time information about
status of the enclosure hardware.
Click on the expander button to display current conditions and status of the enclosure, power
supplies, fans, browsers, temperature sensors and voltage sensors.
In the virtual enclosure that appears at the top of the menu, move the cursor over the icon to
view the statistics on status and relevant conditions of the fans, power supplies, and
temperature sensors.
Enclosure information menu
15.2
Temperature sensor settings
When the internal temperature reaches a high level, the temperature threshold settings is
used to send event notifications.
To set enclosure temperature thresholds:
1.
Click
Enclosures
in the tree view.
2.
Click the
Settings
tab to view the Enclosure Settings menu.
Two thresholds can be configured:
–
Controller Warning Temperature Threshold [80-95 C°] - If the enclosure temperature
reaches this threshold, a warning message is sent, and the event is recorded in the event
log.
–
Controller Critical Temperature Threshold [100-105 C°] - If the enclosure temperature
reaches this threshold, a warning message is sent, and the event is recorded in the event
log.