64
en | Troubleshooting
CIP5000 series storage
2019-10 | V01 | F.01U.380.030
User manual
Bosch Security Systems B.V.
–
Service Setting - Email
–
Service Setting - Webserver
–
Spare Info - Basic spare drive information
–
Spare Dump Info - Diagnostic information
–
Spare Verbose Info - Full spare Drive
–
information
–
Statistic Info
–
Subsystem info
–
User Info
21.4
How to diagnose the alarm buzzer
When you power up the CIP5000 system for the first time, the alarm buzzer beeps twice to
indicate the system is operating normally.
If the audio alarm sounds at any other time, you need to be aware of the system. However,
buzzer alarms are not specific to this situation. View the device indicators and Events displays
or logs for more information.
When the alarm sounds:
–
Check the red or orange indicators on the front and rear of the enclosure.
–
Check the new messages if the email notification is enabled.
–
Check the event log.
During continuous beeps, the buzzer sounds in various alarm patterns simultaneously.
Alarm buzzer patterns
Pattern 2
Alarm Pattern 2 is three short beeps after a long period of silence and then repeat.
This indicates a serious problem, such as a high enclosure temperature or a system fan is not
installed, that requires immediate solution. When you hear the sound of Pattern 2, check the
System Status LED. If the LED is normal, then it might be a physical drive problem or a PSU
problem, you can check the event log for more information.
Pattern 3
It indicates that LD is offline.
Pattern 4
It indicates that there may be an LD critical sector or a bad sector on the physical disk.
21.4.1
How to disable the alarm buzzer
To disable the alarm buzzer:
1.
Open the Management GUI.
Summary of Contents for CIP-5316-JBOD