21
Maximum usable power for the cooking zones
The right and left cooking zones are controlled by two separate power
boards and the maximum total power per each power board is 3700 W.
Should the cooking zones of one power board require more than 3700 W,
the last selected power level has priority and the power of the other cooking
zone is automatically reduced to the remaining power available. If this
occurs, the cooking zone will display a flashing figure for about 3 seconds
before automatically displaying the new power level.
This means for example that:
*
When setting a “Booster” programme for the second zone, the
setting for the other zone could be reduced to the remaining power
available.
*
When setting a “Booster” programme for a zone and then another
setting on the second zone, if the total power exceed 3700 W the
“Booster” programme is deleted and the power reduced to the
maximum power available.