72
BONMET motion GmbH/www.bonmet.com/www.bonmet.de
Details
:
This parameter is used for DSP and application interaction, the application queries the value of the parameter to determine
the EEPROM operation is completed or not.
Value
Function
0
Operation completed successfully
1
Operation in progress
2
Operation failed
R-10
Parameter
FPGA version
Modbus address
0x1C64
Unit
-
Range
-
Default
-
CANbus object
-
Attrib
RO
Control mode
:
All
Details
:
FPGA version number is stored in this parameter for application inquiry
R-11
Parameter
Index Reset Status
Modbus address
0x1C65
Unit
-
Range
-
Default
-
CANbus object
-
Attrib
RO
Control mode
:
All
Details
:
This parameter instructs encoder counter to complete index reset operation or not.
Value
Function
0
Home position reset completed
1
W phase signal of encoder
2
V phase signal of encoder
3
U phase signal of encoder
R-12
Parameter
Index reset encoder counts
Modbus address
0x1C66
Unit
-
Range
-
Default
-
CANbus object
-
Attrib
RO
Control mode
:
All
Details
:
This parameter is used to latch encoder count value when index reset operation carried out. The hardware carries out latch
operation during home position reset operation, the parameter is used to guarantee the coherence of pulse counting.
R-13
Parameter
Real-time encoder counts
Modbus address
0x1C67
Unit
-
Range
-
Default
-
CANbus object
-
Attrib
RO
Control mode
:
All
Details
:
This parameter indicates the current value of the encoder counter, the unit is pulse. This parameter reflects the physical
location of the motor shaft
R-14
Parameter
CN2 input terminal status
Modbus address
0x1C68
Unit
-
Range
-
Default
-
CANbus object
-
Attrib
RO
Control mode
:
All
Details
:
This parameter indicates the digital input status of CN2 input interface.
Value
Function
Value
Function
0
PulseInv status
5
CCWLtd status
1
SignInv status
6
CWDis status
2
INH status
7
CCWDis status
3
CLE status
8
AlarmClr status