79
BONMET motion GmbH/www.bonmet.com/www.bonmet.de
Error Check (CRC)
––
Response
The normal response returns the slave address, function code, starting address, and quantity of registers preset.
Here is an example of a response to the query shown above.
RESPONSE
Example
Field Name
(Hex)
Slave Address
11
Function
10
Starting Address Hi
00
Starting Address Lo
01
No. of Registers Hi
00
No. of Registers Lo
02
Error Check (CRC)
––
Chapter 7 Protective Function
8.1
Alarm List
Alarm code
Protective function
0
Normal state
1
System error
2
Z phase error protection
3
Hall(U/V/W phase) signal error protection
4
A/B phase signal error protection
5
Encoder counter missing error
6
Overcurrent protection of power module
7
Main circuit relay disconnected
8
Overvoltage
9
Undervoltage
10
Motor (IR
2
) overheat protection
11
Motor phase current gain error
12
EEPROM operation error
13
Drive overheat protection
14
Over-regeneration load protection
(NOT SUPPORT)
15
Over-travel inhibition error
16
Excessive deviation
17
Reservation
18
Torque overload alarm