BLUEBOX CX Industrial UHF
Page 41 of 126
Parameter
Description
Range
Default
Port
‘Spontaneous’ message remote server
TCP
communication
port.
0
to
disable
the
‘spontaneous’ message as TCP client, 80 or 8080
to enable the ‘spontaneous’ message with HTTP
POST messages.
Note that this parameter become effective
only after a reboot of the reader.
0 … 65535
0
Connection
Time
‘Spontaneous’ message remote server
maximum
connection time.
Note that this parameter become effective
only after a reboot of the reader.
1 … 99
seconds
1 … 99
minutes
1 sec
HTTP POST
Page
The ‘spontaneous’ message HTTP POST page.
Note that this parameter become effective
only after a reboot of the reader.
240 chars null
terminated
string
“”
Auto LAN IP
Address
Auto connection remote server IP address. 0.0.0.0
to disable the auto connection.
Note that this parameter become effective
only after a reboot of the reader.
IPv4
0.0.0.0
Auto LAN Port
Auto connection remote server communication
port. 0 to disable the auto connection, 80 or 8080
to enable the auto connection with HTTP POST
messages.
Note that this parameter become effective
only after a reboot of the reader.
0 … 65535
0
Auto LAN
Connection
Time
Auto connection remote server maximum
connection time.
Note that this parameter become effective
only after a reboot of the reader.
1 … 99
seconds
1 … 99
minutes
1 sec
Auto LAN
HTTP POST
Page
The auto connection HTTP POST page.
Note that this parameter become effective
only after a reboot of the reader.
240 chars null
terminated
string
“”
The remote server parameters are stored in configuration page nr. 0x81, 0xC1
and 0xC2 and are managed through the
‘Read
RAM/ROM Configuration
Parameters’ and ‘Write
RAM/ROM
Configuration Parameters’
commands as