BLUEBOX CX Industrial UHF
Page 23 of 126
Status Display
3 LEDs, Buzzer
Connections
3 M12 Connectors (5-poles A-coded male for
power supply, 12-poles A-coded female for
I/O, 4-poles D-coded female for Ethernet)
2.1.7
Electrical Features 5337U-rrr
Power Supply
10 … 36 Vdc
Power Rating
15W @RFout=30dBm
Operating Frequency
EU1: 865 MHz … 868 MHz
FCC: 902 MHz … 928MHz
BRA: 902 MHz … 928 MHz
RF Transmit Power
Max 1W (30dBm) conducted
RF Receive Sensitivity
Max -85dBm
Antenna
1 external
Antenna Connection
TNC female, 50 Ω
Reading Distance
10 mt
13
Supported Transponders
ISO 18000-63
14
(EPC Class-1 Gen-2 V2)
Communication Interface
Serial RS232 / RS485
Data bus (Wiegand Data-0, Data-1)
Service Interface
USB Virtual Com (on the board and not
available on the external)
Digital Inputs
2 opto-
isolated input, 10Vdc … 36Vdc, Max
current 20mA @24Vdc, debounce 16ms
Digital Outputs
2 outputs (relay), NO/NC contacts, Max 1A
@30Vdc
Status Display
3 LEDs, Buzzer
Connections
3 M12 Connectors (5-poles A-coded male for
power supply and serial interface, 12-poles
A-coded female for I/O, 5-poles A-coded
female for data bus)
13
Reading distance depends on transponder type, antenna and environmental conditions.
14
ISO 18000-6C became ISO 18000-63 in 2012 due to ISO naming rules that do not allow letters in standards names.