BLUEBOX CX Industrial UHF
Page 47 of 126
3.2.6
CAN Bus Interface
This section provides details on the configurable CAN bus interface parameters
of the
BLUEBOX
Parameter
Description
Range
Default
Node ID
The CAN bus node ID of the reader.
Note that this parameter become effective
only after a reboot of the reader.
See protocol
technical
manual
See protocol
technical
manual
Bitrate
The CAN bus bitrate.
Note that this parameter become effective
only after a reboot of the reader.
See protocol
technical
manual
See protocol
technical
manual
The CAN bus interface parameters are stored in configuration page nr. 0x83 and
ar
e managed through the ‘Read RAM/ROM Configuration Parameters’ and ‘Write
RAM/ROM Configuration Parameters’ commands as described in protocol
technical manuals where the paramete
rs 1…14 fields with default values are:
1
2
3
4
5
6
7
Network
Address
Baud Rate
0x00
0x00
0x00
0x00
0x00
..
..
0x00
0x00
0x00
0x00
0x00
8
9
10
11
12
13
14
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Where:
Parameter
Description
Network
Address
The CAN bus network address of the reader.
Baud Rate
The CAN bus baud rate:
•
0x00: 10 kbit/s
•
0x01: 20 kbit/s
•
0x02: 50 kbit/s
•
0x03: 100 kbit/s
•
0x04: 125 kbit/s
•
0x05: 250 kbit/s