BLUEBOX CX Industrial UHF
Page 63 of 126
Where:
Parameter
Description
ReadAfterDete
ct Password0
….
ReadAfterDete
ct Password3
The passwo
rd to be used to access to tag’s memory in ReadAfterDetect mode. Use a ‘0’
password if the access password is not requested.
ReadAfterDete
ct Bank
The tag’s memory bank to access in ReadAfterDetect mode:
•
0x00: Reserved;
•
0x01: EPC;
•
0x02: TID;
•
0x03: User.
ReadAfterDete
ct Address0
…
ReadAfterDete
ct Address3
The tag’s memory start addre
ss to access in the specified memory bank in
ReadAfterDetect mode.
ReadAfterDete
ct Length
The number of tag’s memory blocks (2
-bytes length) to access in the specified memory
bank in ReadAfterDetect mode. In case of Reserved or User bank selected, 0 means no
tag’s memory block access; in case of TID bank selected, 0 means auto
-length (class
identifier, manufacturer identifier, serial number).
ReadAfterDete
ct Info Flags
The tag’s info (PC, EPC, CRC) to include in the tag’s ID in ReadAfterDetect mode. A byt
e
whose bits are dedicated to disable (0 value) or enable (1 value) functions:
Bit
Description
Bit 7
Not used
Bit 6
Not used
Bit 5
Not used
Bit 4
Not used
Bit 3
Not used
Bit 2
CRC field
Bit 1
EPC field
Bit 0
PC field
Q
Minimum and maximum Q value to be used in dynamic Q selection algorithm:
•
High nibble: minimum Q value (0x0 … 0xF);
•
Low nibble: maximum Q value (0x0 … 0xF).
Q Adjust
Rounds
Maximum Q adjust rounds in dynamic Q selection algorithm.
Inventory
Cycles
The inventory cycles in inventory command.