BLUEBOX CX Industrial UHF
Page 38 of 126
Parameter
Description
Range
Default
Mode with
Inputs
‘Continuous’
Mode
‘Continuous’ mode. If activated overrides the
trigger ‘continuous’ mode with inputs setting.
Disabled
Enabled
Enabled
The general parameters a
re managed through the ‘
Read RAM General
Parameters
’ and ‘
Write ROM
General Parameters’ commands as described in
protocol technical manuals
where the parameters 1…7 fields with
default values
are:
1
2
3
4
5
6
7
Device
Address
Serial1
Serial2
0x00
0x00
Filter Time
Functional
Flags
0xFF
0x48
0x10
0x00
0x00
0x01
0x80
Where:
Parameter
Description
Device
Address
Device
address of the reader on serial interface in the range 0 … 255
.
Serial1
Serial interface communication settings.
•
High nibble: baud rate:
o
0x0: 1200 bps;
o
0x1: 2400 bps;
o
0x2: 4800 bps;
o
0x3: 9600 bps;
o
0x4: 19200 bps;
o
0x5: 38400 bps.
•
Low nibble: data bits:
o
0x7: 7 bits;
o
0x8: 8 bits.
Serial2
Serial interface communication settings.
•
High nibble: stop bits:
o
0x1: 1 bits;
o
0x2: 2 bits.
•
Low nibble: parity:
o
0x0: None;
o
0x1: Even;
o
0x2: Odd.
Filter Time
Reading management filter time (0 setting is internally overwritten with 1 second):
•
Decimal 0 … 99 for time in seconds (0 …
99 seconds);