Parameter
Description
•
Decimal 100 … 199 for time in minutes (0 …
99 minutes).
Functional
Flags
Flags. Single bits are dedicated to disable (0 value) or enable (1 value) functions:
Bit
Description
Bit 7
Automatic buzzer management
Bit 6
Automatic output 1 management
Bit 5
Reading antenna information
Bit 4
Transponder type information
Bit 3
‘Spontaneous’ mode
Bit 2
Transponder detection timestamp information
Bit 1
‘Continuous’ mode with inputs
Bit 0
‘Continuous’ mode (0=enabled, 1=disabled).
3.2
Configuration Parameters
This section provides details on the configurable operational parameters of the
BLUEBOX
.
3.2.1
Ethernet Interface
This section provides details on the configurable Ethernet interface parameters
of the
BLUEBOX
Parameter
Description
Range
Default
IP Address
IP address.
Note that this parameter become effective
only after a reboot of the reader.
IPv4
192.168.4.200
Port
Communication port.
Note that this parameter become effective
only after a reboot of the reader.
0 … 65535
3000
Subnet
Subnet mask.
Note that this parameter become effective
only after a reboot of the reader.
IPv4
255.255.255.0
Gateway
Gateway address.
Note that this parameter become effective
only after a reboot of the reader.
IPv4
0.0.0.0
The Ethernet interface parameters are stored in configuration page nr. 0x80 and
are managed through the ‘
Read RAM/ROM Configuration Parameters
’
and ‘
Write