33
AQT8 Series
User Manual
11.4 “System” Tab (continued)
Reboot
This section allows the user to reboot the unit from this screen.
Click this button to reboot the unit.
5
System Settings Configuration
This section allows the user to back-up and re-load the configuration settings.
Resets the unit back to the Factory defaults. It is always recommended to save the
existing configuration file before resetting to the default values .
Downloads the current unit configuration file.
Browse and select a Configuration File.
After choosing file, click this to load and apply the configuration file.
1
4
2
3
General System Configuration
This section allows the user to enter user-defined identification data.
Unit Name: a user-defined field to more easily identify the unit by name.
The character limit is 64 alphaumeric, however
if other characters are used, the display limit is decreased and may truncate.
Unit Location: a user-defined field to more easily identify the unit's location.
The character limit is 64 alphaumeric,
however if other characters are used, the display limit is decreased and may truncate.
6
7
Ethernet Settings Configuration
This section allows the user to set up the network settings for the unit.
Control Port IP Address: the static IP address that is assigned to the GbE Control
port, allowing the user to access the
unit via the web interface. (Factory Default: “172.16.70.1”)
Control Port Subnet Mask:
the Subnet Mask address assigned to the
GbE Control
port of the unit, allowing the user to
determine which subnet the Control Port IP address belongs to. (Factory Default: “255.255.255.0”)
Control Port Default Gateway: the gateway address assigned to the GbE Control
port, allowing the user to access the
unit from another network via the web interface. (Factory Default: “172.16.70.254”)
8
9
10
Remember to click on the SAVE button to apply the new values/configurations.
REMINDER: If the Control port's IP address is changed, the unit will reboot and be located at the new IP address.
11
14
12
15
13
16
Data Port IP Address: the static IP address assigned to the
Data
port. (Factory Default: “192.168.253.1”)
Data Port Subnet Mask:
the subnet mask address assigned to the Data
port. (Factory Default: “255.255.255.0”)
Data Port Default Gateway:
the gateway address assigned to the Data
Port. (Factory Default: “192.168.253.254”)
EAS Port IP Address: the static IP address assigned to the IP EAS IN Port. (Factory Default: “192.168.252.2”)
EAS Port Subnet Mask:
the Subnet Mask address assigned to the
IP EAS IN Port. (Factory Default: “255.255.255.0”)
EAS Port IGMP Version: the selection of IGMP version between IGMPv2 and IGMPv3. (Factory Default: “IGMPv2”)