Problem: All wrench & manipulator functions are inoperative.
No
No
No
Is there 2,500 psi
present at system pressure
gauge?
Is 2,500 psi present at
H.P.U output?
Trouble shoot
Hydraulic
Power Unit.
The return line is
probably loose.
Check the quick
disconnect fitting.
Are all valves in the system
open?
Open related
valves.
The problem is most likely a
loose pressure quick disconnect.
Yes
Yes
Yes
START