72
MINI-MODEM V.92
7.2.4 D
IRECT
C
ONNECTION
Use this procedure when you want to connect without first being called back. The
password that you use must be set up for an optional direct connection.
1. Using a data communications program such as HyperTerminal or
PhoneTools, dial the number of the callback modem.
2. When the connection is established, the callback modem responds with the
following message:
Password>
.
3. Type a direct connection password, press the - key, and then press ENTER.
You have three attempts or one minute to enter a valid password.
4. If the password is valid, the following message appears and the modems
establish a working connection:
OK Connecting
.
NOTE
You can make all calls direct connect regardless of whether the
password or phone number has the - character by using the %H1
command
7.3 Callback Security Commands
The following AT commands are used with callback security. Most can be entered
only after the setup password has been entered.
Command:
#CBAn
Callback Attempts
Values:
n = 1–255
Default: 4
Description:
Sets the number of callback attempts that are
allowed after passwords have been exchanged
between modems. This command can be used only
after the setup password has been entered and
callback security enabled.
Command:
#CBDn
Callback Delay
Values:
n = 0–255
Default:
15
Description:
Sets the length of time (in seconds) that the modem
waits before calling back the remote modem. This
command can be used only after the setup password
has been entered and callback security enabled.