52
MINI-MODEM V.92
0
Maximum rate determined by the modulation
selected in mod (default).
300–56000
Maximum rate value limited by the modulation
selected in mod. See “Possible rates” in the mod table.
Command:
+PCW=n
Call Waiting Enable
Values:
n = 0, 1, or 2
Default:
2
Description:
Controls the action to be taken upon detection of a
call waiting tone in V.92 mode. Values specified by
this command are not modified when an AT&F
command is issued.
+PCW=0
Toggles V.24 Circuit 125 and collects Caller ID if
enabled by +VCID
+PCW=1
Hangs up
+PCW=2
Ignores V.92 call waiting
+PCW=?
Displays the allowed values
+PCW?
Displays the current value
Command:
+PIG=n
PCM Upstream Ignore
Values:
n = 0 or 1
Default: 1
Description:
Controls the use of PCM upstream during V.92
operation. PCM upstream allows faster upload
speeds to a V.92 server.
+PIG=0
Disables PCM upstream
+PIG=1
Enables PCM upstream
+PIG=?
Displays the allowed values
+PIG?
Displays the current value
Command:
+PMH=n
Modem on Hold Enable
Values:
n = 0 or 1
Default: 1
Description:
Controls if modem on hold procedures are enabled
during V.92 operation. Normally controlled by a
modem on hold program. Values specified by this
command are not modified when an AT&F
command is issued.
+PMH=0
Enables V.92 modem on hold
+PMH=1
Disables V.92 modem on hold
+PMH=?
Displays the allowed values
+PMH?
Displays the current value