38
MINI-MODEM V.92
Command:
&Dn
Data Terminal Ready (DTR) Control
Values:
n = 0, 1, 2, or 3
Default: 2
Description:
&D0
Modem ignores the true status of the DTR signal
and responds as if it is always on.
&D1
If DTR drops while in on-line data mode, the
modem enters command mode, issues an OK, and
remains connected.
&D2
If DTR drops while in on-line data mode, the
modem hangs up. If the signal is not present, the
modem will not answer or dial.
&D3
If DTR drops, the modem hangs up and resets as if
an ATZ command were issued.
Command:
&En
XON/XOFF Pacing Control
Values:
n = 12 or 13
Default: 12
Description:
&E12
Disables XON/XOFF pacing.
&E13
Enables XON/XOFF pacing. (&K4 must also be
set.) &E13 has no effect if hardware control
(&K3) is selected.
Command:
&Fn
Load Factory Settings
Values:
n = 0
Default:
None
Description:
&F0
Loads factory settings as active configuration. (See
also the Z command.)
Command:
&Gn
V.22 bis Guard Tone Control
Values:
n = 0, 1, or 2
Default: 0
Description:
&G0
Disables guard tone.
&G1
Sets guard tone to 550 Hz.
&G2
Sets guard tone to 1800 Hz.
Note that the &G command is not used in North
America.
Command:
&Kn
Flow Control Selection
Values:
n = 0, 3, or 4
Defaults: 3
Description:
&K0
Disables flow control.
&K3
Enables CTS/RTS hardware flow control.
&K4
Enables XON/XOFF software flow control.