BINKS EMS | OPERATION MANUAL
8.15 Calibration — Resin Only
This screen is used to check the Flow Meter calibration ONLY. Performing a calibration using this screen will flow paint
resin without hardener through the system, and should be followed by a color 0 flush / load. This calibration is used to more
accurately calibrate the Flow Meter or troubleshoot the Dispense Pump if necessary.
1. Flow Meter cc/pulse
This is the cc’s per pulse
delivered in the system. This number will need to
be calibrated for each individual color. Default is
.2400
2. Pulse Count
Counts the number of Flow Meter
pulses received during the calibration test.
3. Expected Volume (cc)
This is PLC’s calculation
of total volume at the current Flow Meter cc/
pulse and programmed ratio.
4. Measured Volume (cc)
This is a user input.
Enter the measured volume after triggering the
gun for a specified time. Press F3 (Save) after
entering the Measured Volume.
5. Calculated cc/pulse
After a new measured
volume is entered the new cc/pulse will be
displayed in this box. This is a preview of the
new cc/pulse.
The Save button (F3) must be
pressed to accept the new value.
6. START
This button (F2) will reset the expected
volume and pulse count to zero. Press this before
every calibration.
7. SAVE
(not shown) This key will appear when a
new value is typed into the Measured Volume
box, and the enter key is pressed. Pressing F3
(SAVE) calculates and saves the new cc/pulse
value.
8. NEXT
Pressing F4 (NEXT) will advance to the
Alarm Enables screen.
1
2
3
4
5
6
8
7
NOTE
Use the Resin + Hardener Calibration first. This calibration procedure
will load uncatalyzed material in fluid lines and will require a solvent
flush after performing. Only accessible with the Advanced password.
Always follow Resin Only calibrations with a Color 0 flush / load.
Saving only possible with Advanced Password.