8.14 Calibration — Resin+Hardener
This screen is used to check the ratio of the mixed material without interrupting the flow of mixed material through the
system. This is the screen used to calibrate the Flow Meter when loading a new color as outlined by the
Binks EMS
Maintenance and Repair Manual 77-2981
.
1. Flow Meter cc/pulse
This is the cc’s per pulse
delivered in the system. This number will need to
be calibrated for each individual color. Default is
.2400
2. Pulse Count
Counts the number of Flow Meter
pulses received during the calibration test.
3. Expected Volume (cc)
This is PLC’s calculation
of total volume at the current Flow Meter cc/
pulse and programmed ratio.
4. Measured Volume (cc)
This is a user input.
Enter the measured volume after triggering the
gun for a specified time. Press F3 (Save) after
entering the Measured Volume.
5. Calculated cc/pulse
After a new measured
volume is inputted, the new cc/pulse will be
displayed in this box. This is a preview of the new
cc/pulse.
The Save button(F3) must be pressed
to accept the new value.
6. START
This button (F2) will reset the expected
volume and pulse count to zero. Press this button
twice before every calibration.
7. SAVE
(not shown) This key is used after a new
value is typed into the Measured Volume field
and the enter key is pressed. Pressing F3 (SAVE)
calculates and saves the new cc/pulse value.
8. NEXT
Pressing F4 (NEXT) will advance to the next
Calibration screen.
1
2
3
4
5
6
8
7
NOTE
The machine must be in MIX mode to perform a calibration.
Always follow any saved calibration with a Color 0 load.
Saving only possible with Advanced Password.