15
BINKS EMS | OPERATION MANUAL
6.1
Air Connections
(cont.)
A25
A26
A11
A23
A24
A21
A22
A6
A28
A1
A20
A7
A8
A9
A10
A19
A18
A17
A16
A12 A13 A14 A15
Bottom view of control enclosure
NUMBER
TYPE
DESCRIPTION (HOSE LABEL)
CONNECTING
THREAD
HOSE ID /
TUBE OD
A1
Hose
Main air inlet
1/4 nps male
5/16”
A2
Hose
Inlet to air flow switch gun 1
1/4 nps male
5/16”
A3
Hose
Outlet from air flow switch gun 1
1/4 nps male
5/16”
A4
Hose
Flushing air to mix manifold
1/4 nps male
5/16”
A5
Hose
Flushing air to color stack
1/4 nps male
5/16”
A6
Poly
Dispense pump top inlet trigger
5/32"
A7
Poly
Dispense pump bottom inlet trigger
5/32"
A8
Poly
Dispense pump top outlet trigger
5/32"
A9
Poly
Dispense pump bottom outlet trigger
5/32"
A10
Poly
Resin Enable trigger
5/32"
A11
Poly
Flush air trigger
5/32"
A12
Poly
Flush solvent trigger
5/32"
A13
Poly
Color 1 trigger
5/32"
A14
Poly
Color 2 trigger
5/32"
A15
Poly
Color 3 trigger
5/32"
A16
Poly
Color 4 trigger
5/32"
A17
Poly
Color 5 trigger
5/32"
A18
Poly
Color 6 trigger connection or
Gun Flush Box trigger 2 connection
5/32"
A19
Poly
Gun Flush Box trigger 1 connection
5/32"
A20
Poly
Not in use
5/32"
A21
Poly
Air flow switch 1 signal connection
5/32"
A22
Poly
Air flow switch 2 signal connection
5/32"
A23
Poly
Gun In Box 1 signal connection
5/32"
A24
Poly
Gun In Box 2 signal connection
5/32"
A25
Poly
Not In Use
——
A26
Poly
Not In Use
——
A27
Poly
Optional atomization air shut-off signal
1/4"
A28
N.C.
Solenoid Exhaust Port
1/4"