16
BINKS EMS | OPERATION MANUAL
6.2
Air Connection Descriptions
A1
Main air to the system cabinet; powers all
solenoids and flush boxes if equipped. 1/4” NPS
male connection. Make sure air supplied to the
cabinet is clean and is between working pressures.
A2 GUN 1
Atomizing air inlet to gun 1. 1/4” NPS
male connection. Requires clean, regulated air from
20 to 100 psi (1.5 to 7 bar) as appropriate for paint
atomization.
A2 GUN 2
Atomizing air inlet to gun 2. 1/4” NPS
male connection. Requires clean, regulated air from
20 to 100 psi (1.5 to 7 bar) as appropriate for paint
atomization.
A3 GUN 1
Atomizing air outlet (to gun 1). 1/4” NPS
male connection. Connect air hose to air inlet of
spray gun 1.
A3 GUN 2
Atomizing air outlet (to gun 2). 1/4” NPS
male connection. Connect air hose to air inlet of
spray gun 2.
A4
Air Flush to mix manifold. Equipped with a
check valve at the inlet. Connect air supply to ball
valve.
A5
Air Flush to color stack. Equipped with a check
valve.
A6
Top inlet poppet valve and solenoid connection.
A7
Bottom inlet poppet valve and solenoid
connection.
A8
Top outlet poppet valve and solenoid
connection.
A9
Bottom outlet poppet valve and solenoid
connection.
A10
Resin Enable poppet valve and solenoid
connection.
A11
Air enable poppet valve and solenoid
connection. This connection is made on the color
stack when multiple colors are ordered or on the
mix manifold when auto flush is ordered with one
color.
A12
Solvent enable poppet valve and solenoid
connection. This connection is made on the color
stack when multiple colors are ordered or on the
mix manifold when auto flush is ordered with one
color.
A13
Color 1 poppet valve and solenoid connection.
A14
Color 2 poppet valve and solenoid connection.
A15
Color 3 poppet valve and solenoid connection.
A16
Color 4 poppet valve and solenoid connection.
A17
Color 5 poppet valve and solenoid connection.
A18
Color 6 poppet valve and solenoid connection
or Gun Flush Box trigger 2 signal.
A19
Gun Flush Box 1 trigger signal.
A20
Not In use
A21
Air flow switch gun 1 “flow detected” signal
and pneumatic/electric switch.
A22
Air flow switch gun 2 “flow detected” signal
and pneumatic/electric switch.
A23
Gun in box gun 1 signal lets the system know
that the gun is locked in the box and is ready to
flush or load.
A24
Gun in box gun 2 signal lets the unit know that
the gun is locked in the box and is ready to flush or
load.
A25
Not in use.
A26
Not in use.
A27
Optional atomization air shut-off signal
A28
Air exhaust port to allow air from solenoids to
vent. No connection needed.