Chapter 7 – Trouble Shooting & Maintenance
7-9
2)
Power Component Check – 50 HP ~ 125 HP
Module
Test polarity
Reading
Module
Test polarity
Reading
+
-
+
-
DC Bus
Fuse
Fuse 1
across fuse
Closed
Fuse
Indicator
Fuse 1
across
indicator
Closed
SCR's
*SCR1
D1
R P2
(+) Open
Diodes
D4
R N
(-) Open
P2 (+)
R
Open
N (-)
R
Closed
SCR2
S P2
(+) Open
D5
S N
(-) Open
P2 (+)
S
Open
N (-)
S
Closed
SCR3
T P2
(+) Open
D6
T N
(-) Open
P2 (+)
T
Open
N (-)
T
Closed
* measurement is across Rpre/D1 (series) in parallel with SCR1
A 125 HP has 6 SCR/Diode modules (SCR1a, SCR2a, D1a, D2a, etc.)
IGBT's
Tr1
U P2
(+)
Closed
IGBT's
Tr4
U N
(-) Open
P2 (+)
U
Open
N (-)
U
Closed
Tr3
V P2
(+)
Closed
Tr6
V N
(-) Open
P2 (+)
V
Open
N (-)
V
Closed
Tr5
W P2
(+)
Closed
Tr2
W N
(-) Open
P2 (+)
W
Open
N (-)
W
Closed