9
126305 Rev B 05/22/15
Once the proper “code” is pressed “Manager Mode: 00” will
be displayed at the top of the screen (see figure 3.3).
NOTE:
If the module is left in Manager’s Mode for 60
seconds without any keys pressed, the unit will
automatically return to normal operation.
Programming Modes:
There are four modes that will need to be programmed prior
to the module operating per the location’s specifications.
•
Mode 01
-
Address
•
Mode 12
-
Receipt Length
•
Mode 13
-
Keypad Type
•
Mode 14
-
Receipt Delay
•
Mode 94
-
Line Shift
•
Mode 99
-
Logo
The other modes are for diagnostics and will be discussed in
the Service Section.
Manager’s Mode 01:
There is only one mode that must be programmed for the
module to communicate with the P.O.S. Address the module
through Manager’s Mode 01.
As soon as the module is in Manager’s Mode press the
numeric [1] key and press the function [Enter] key. The
function [Enter] key will be used to enter each mode for
programming or diagnostics.
Once the function [Enter] key is pressed the display will show
which address it is currently configured for (see figure 3.4).
At this time press the proper address for that module.
NOTE:
Use the same address in the module as the
Fueling Point for that dispenser.
As soon as the numeric number for the address is pressed
the display will show what the new address is (see figure
3.5).
Now that the proper address is being displayed press the
function [Enter] key. Once pressed the previous display will return with the new address. After this is
complete press the right Soft Key where “EXIT” is present on the display to exit Manager’s Mode 01.
If programming is complete press the right Soft Key next to “EXIT” on the display again and the module
will return to normal operation.
Programming
(continued...)
Figure 3.3
-
Mode 00
Figure 3.4
-
Mode 01
Figure 3.5
-
New Address Set