24
126305 Rev B 05/22/15
Service
Service
(continued...)
Manager’s Mode 10:
Once the module is in Manager’s Mode press the numeric [1]
and [0] keys and press the function [Enter] key.
This mode is used to display the maximum queues. This is
for Diagnostic and Development purposes only. Press the
bottom right Soft Key, where “EXIT” is present, to exit out of
Manager’s Mode 10.
Manager’s Mode 96:
This mode is used to view the communication performance
between the POS and the module.
Once the module is in Manager’s Mode press the numeric [9]
and [6] keys and press the function [Enter] key.
•
FE: shows the total number of messages started. Every
time a character causes the start of a new message, the
FE Counter is incremented (see figure 4.18).
•
Valid: shows the total number of valid messages
received and validated (see figure 4.18).
•
Percent: The percent shows the total up time, in
percentage, for the communication link (see figure 4.18).
NOTE:
Each module only counts the number of times a
new message is started and the number of times
a valid message is received, regardless of the
source or destination address of the message.
The top right soft key can be used to clear the
communication counters any time. Cycling power also clears
the counters. The communication performance has an
accuracy of 0.01%.
Press the bottom right Soft Key, where “EXIT” is present, to
exit out of Manager’s Mode 96.
FIGURE 4.18
-
Mode 96