Bennett CNG Spec.100 Series Operators Manual
Diagnostics
47
6.6 EEPROM UPDATE STARTS
This code is used to tell the technician how many times a reset occurred during an EEPROM update on the dispenser.
1.
To enter this test, enter diagnostics and press the
6
button on the keypad and the
[
ENTER
] button.
The main display shown in
Figure 5.19
appears. The PPM display shows the
dispenser is in Diagnostics Level 6.5.
The number resets occurred during an EEPROM update appears on the second
line of the main display.
2.
Press the [
CANCEL
] button to exit this test.
3.
Press the [
CANCEL
] button twice to exit Diagnostics.
ADDITIONAL COUNTERS
This code is used to tell the technician how many times a Modbus, Meter, or Dispenser error has occurred. Refer to the table below for
counter descriptions.
1.
To enter this test, enter diagnostics and press the
6
button on the keypad and the [
ENTER
]
button.
The main display shown in
Figure 5.20
appears. The PPM display shows the dispenser
Diagnostics Level (e.g. 6.7).
Refer to the table below for error text displayed.
The number resets occurred appears on the second line of the main display.
2.
Press the [
CANCEL
] button to exit this test.
3.
Press the [
CANCEL
] button twice to exit Diagnostics.
COUNTER DESCRIPTION
CODE TEXT
COUNTER DESCRIPTION
REASON
6.7
QERR1
Side 1 – Modbus Secondary Response Failure Counter
Indicates a problem with communication
hub/meter connection
6.8
QERR2
Side 2– Modbus Secondary Response Failure Counter
Indicates a problem with communication
hub/meter connection
6.9
QTOT1
Side 1 - Modbus master (dispenser) request/response re-transmit
counter
Message timeout from Side 1 Modbus
6.10
QTOT2
Side 2 - Modbus master (dispenser) request / response re-transmit
counter
Message timeout from Side 2 Modbus
6.11
RSPFL1
Side 1 – Modbus secondary response transmission failure counter
6.12
RSPFL2
Side 2 – Modbus secondary response transmission failure counter
6.13
F1
Side 1 – Meter status register that contains reason for meter alarm
Error code reported by the Side 1 meter
the last time a critical error occurred
6.14
F2
Side 2 – Meter status register that contains reason for meter alarm
Error code reported by the Side 2 meter
the last time a critical error occurred
6.15
D1
Side 1 – Reason dispenser shutdown
Shutdown code for last transaction
performed on Side 1 of the dispenser
6.16
D2
Side 2 – Reason dispenser shutdown
Shutdown code for last transaction
performed on Side 2 of the dispenser
FIGURE 5.19 – EEPROM RESETS COUNTER
Sale $
estart
GGE
0
Diag
--6.6
FIGURE 5.20 – ADDITIONAL COUNTER
Sale $
Qerr1
GGE
0
Diag
--6.7
Summary of Contents for CNG Spec. 100 Series
Page 3: ...Bennett CNG Spec 100 Series Operators Manual Bennett Limited Warranty i...
Page 4: ...Bennett CNG Spec 100 Series Operators Manual ii Page Intentionally Left Blank...
Page 46: ...Bennett CNG Spec 100 Series Operators Manual Programming 40 Page Intentionally Left Blank...
Page 56: ...Bennett CNG Spec 100 Series Operators Manual Diagnostics 50 Page Intentionally Left Blank...