TO READ THE TOTAL NU MBER OF SALES AND TO TAL NUMBER OF PRICE CHANGES, FOLLOW THIS PROCEDURE:
1.
Press the
Up-Arrow
(↑) button. The PPV display indicates Product 1 counter totals.
The ‘Total Sale’ display shows the number of sales for Product 1. The sales counter is
incremented each time a sale is ran on that nozzle. The ‘Volume’ display shows the
number of price changes for Product 1. The price change counter is incremented each
time a price is changed for that nozzle. Refer to
Figure 3.6.
2.
To read the counter totals for the remaining hoses, press the [
ENTER
] button to cycle
through the counter (money, mass, counter) totals for the remaining hoses or select
1
for money total,
2
for mass totals, or
3
for counters number buttons.
3.
Press the [
CANCEL
] button to exit this menu.
HOW TO READ ELECTRON IC TOTALS WITH THE MAGNETIC REED SWITCH
The operator and/or attendant can use this method to read daily or weekly electronic totals without opening the electronic head of the
dispenser.
TO READ THE MENU CODE 1 TOTALS WITH THE MAGNETIC REED SWITCH, FOLLOW THIS PROCEDURE:
1.
To enter the totals mode, hold the black Access Magnet over the left side of the mass display
print beside the main display as shown in
Figure 3.7
. When the first Money totals appear,
remove the magnet. The display appears as in
Figure 3.4
with P11.1 showing in the PPM window
to indicate the first Money total for Product 1.
NOTE:
If the magnet is not tapped over the mass display print for 30 seconds, the
display returns to the idle screen and the sequence must be started over.
2.
Tap the magnet over the mass display print again to read the Mass Totals for Product 1.
P12.1
is displayed in the PPM display to indicate the first Mass Total for Product 1 as shown in
Figure
3.5
.
3.
Tap the magnet over the mass display print again to read the Counters Totals, which is the
Number of Sales and Number of Price Changes for Product 1.
P13.1
is displayed in the PPM
display to indicate the first Counter Totals for Product 1 as shown in
Figure
3-6.
NOTE:
If Menu Code 2 totals are being read or the re-settable meter totals,
continue with Step 5. If not, wait 30-seconds for the displays to return
to the idle mode, or lift a pump handle to the ON position to return to
the idle mode.
4.
Tap the magnet over the mass display print again and the Money Totals for Product 2
appear. Repeat steps 2 and 3 for the Product 2 totals and the remaining hoses on this
side of the dispenser.
5.
If all Menu Code 1 totals have been displayed, tap the magnet over the mass display
print again as shown in
Figure 3.7
to view the Menu Code 2 (Meter Totals) for Product
1.
Note:
By successively tapping the magnet over the mass display, print the dispenser
moves through the Meter Totals for each hose.
6.
If all Menu Code 2 totals have been displayed, tap the magnet over the mass display
print again to view Menu Code 26 (Resettable Meter Totals) for Product 1 as shown in
Figure 3.8.
NOTE:
These totals can be matched up in Menu Code 5 for the Electro-
Mechanical Totals.
7.
Press the [
CANCEL
] button to exit this menu.
FIGURE 3.6 - SALES TOTALS AND PRICE CHANGE
Sale $
345
GGEs
6
P13.1
Number of Sales
Number of Price Changes
Sale $
456
GGE
7890.12
P1d.1
Menu 26
P1 =
Product 1 Resettable Meter Totals
FIGURE 3.7 – MAGNETIC REED SWITCH
FIGURE 3.8 – RESETTABLE METER TOTALS
Access Magnet
Sale $
0.00
GGE
0.000
Summary of Contents for CNG Spec. 100 Series
Page 3: ...Bennett CNG Spec 100 Series Operators Manual Bennett Limited Warranty i...
Page 4: ...Bennett CNG Spec 100 Series Operators Manual ii Page Intentionally Left Blank...
Page 46: ...Bennett CNG Spec 100 Series Operators Manual Programming 40 Page Intentionally Left Blank...
Page 56: ...Bennett CNG Spec 100 Series Operators Manual Diagnostics 50 Page Intentionally Left Blank...