Bennett CNG Spec. 100 Series Operators Manual
Programming
34
MENU CODE 35 – HOW TO CHOOSE BANK ACTIVATION THAT SIGNALS STATION TO TURN ON COMPRESSORS
CAUTION:
THIS MODE ONLY APPLIES TO CNG 3-BANK DISPENSERS.
Menu Code 35 allows the choice of bank that when activated will trigger the dispenser to signal the station to turn on the station’s
compressors. This mode only applies to CNG 3-Bank Dispensers. This assignment defaults to the high (3
rd
) bank meaning the activation of
the high (3
rd
) bank causes the dispenser to signal the station.
Note:
A CNG 1-Bank dispenser is always set to the default.
1 – Low Bank
2 – Mid Bank
3 – (Default) High Bank
TO SELECT A DIFFEREN T OPTION IN MENU CODE 35, FOLLOW THIS PROCED URE:
1.
Press the number
3
and
5
, then the [
MODE
]
button on the keypad. The PPM display shows
the dispenser is in Menu Code 35. If the dispenser has not been programmed since it came
from the factory, the number 2 appears in the main display. This is the default setting as
shown in
Figure 4.51
.
2.
To change the setting, use the numeric keypad to enter a new option.
Note:
If an error is
made, press the correct number. The new number will replace the error.
3.
When the correct option number appears in the main display, press the [
ENTER
] button to
save the selection.
4.
Press the [
CANCEL
] button to exit this Menu Code.
MENU CODE 44 – SIMULATOR MODE
CAUTION:
THIS PROCEDURE IS ONLY TO BE USED FOR TROUBLESHOOTING. CONTACT BENNETT TECHNICAL SUPPORT
PRIOR TO ENTERING THIS MODE.
IMPORTANT: THE CALIBRATION SWITCH MUST BE UNSEALED IN ORDER TO SET THIS MODE.
Menu Code 44 allows the operator to set the dispenser to operate with PLC & Meter simulation or with Meter Simulation only. When the
dispenser is set to option 2 (Meter Simulation), only the PLC simulation is disabled. This mode is set to 0 (off) by default.
0 – (Default) Off
1 – PLC Pulse & Meter Simulation
2 – Meter Simulation
TO SELECT A DIFFEREN T OPTION IN MENU CODE 44, FOLLOW THIS PROCED URE:
1.
Press the number
4
and
4
, then the [
MODE
]
button on the keypad. The PPM display shows the dispenser is in Menu Code 44. If the
dispenser has not been programmed since it came from the factory, the number 1 appears in the main display. This is the default
setting as shown in
Figure 4.52
.
2.
To change the setting, use
0
,
1,
or
2
button on the keypad to enter a new option as shown in
Figure 4.53
and
Figure 4.54
.
Note:
If an
error is made, press the correct number. The new number will replace the error.
3.
When the correct option number appears in the main display, press the [
ENTER
] button to save the selection.
4.
Press the [
CANCEL
] button to exit this Menu Code.
FIGURE 4.52 – SIMULATOR MODE OFF
Sale $
Set
GGE
off
code
- 44
Sale $
--Set--
GGE
--PLCPUL--
code
- 44
FIGURE 4.53 – PLC PULSE & METER SIMULATION
Sale $
Set
GGE
PULS
code
- 44
FIGURE 4.54 – METER SIMULATION ONLY
FIGURE 4.51 – SIMULATOR MODE OFF
Sale $
banc
GGE
code
- 35
Summary of Contents for CNG Spec. 100 Series
Page 3: ...Bennett CNG Spec 100 Series Operators Manual Bennett Limited Warranty i...
Page 4: ...Bennett CNG Spec 100 Series Operators Manual ii Page Intentionally Left Blank...
Page 46: ...Bennett CNG Spec 100 Series Operators Manual Programming 40 Page Intentionally Left Blank...
Page 56: ...Bennett CNG Spec 100 Series Operators Manual Diagnostics 50 Page Intentionally Left Blank...