Bennett CNG Spec. 100 Series Operators Manual
Programming
25
IDLE TIMEOUT
Idle Timeout
is a programmable feature can be enabled when any activity (the handle is lifted, pressing a button, etc.) is detected at the
dispenser from an idle state or if there is no activity at the dispenser detected for the time equal to the idle timeout the dispenser will
return to its idle state.
TO PROGRAM THE NUMBER OF SECONDS BETWEEN THE TIME THE DISPENSER COMES ON FROM AN IDLE STATE AND
TIMEOUTS, FOLLOW THIS PROCEDURE:
1.
To change the setting, use the
0
through
9
buttons on the keypad to enter a value in
seconds as shown in
Figure 4.30
.
. If the dispenser has not been programmed since it
came from the factory, the number 15 appears in the main display. This is the default
setting.
2.
Press the [
ENTER
] button to save the new setting.
3.
Press the [
CANCEL
] button to exit this Menu Code.
4.
If this is a two-sided dispenser, changing one side will automatically change the second
side to the same value as the first.
MENU CODE 13 – HOW TO SELECT AUDIO TONE OPTIONS
The dispenser can be programmed to emit audio tones when certain buttons are pushed or a pump handle is turned on. The four options
available are:
0 - No audio tones.
1 - Audio tone whenever a button on the keypad is pushed.
2 - Intermittent audio tone whenever an unauthorized pump handle is turned on. The tone stops when the dispenser is
authorized. This option also emits four audio tones at the beginning of a prepay sale.
3 – (Default) Combination of option 1 and 2.
TO SELECT ONE OF THE OPTIONS IN MENU CODE 13, FOLLOW THIS PROCEDURE:
1.
Press the number
1
and
3
, then the [
MODE
] button on the keypad. The price display
shows the dispenser is in Menu Code 13.
If the dispenser has not been programmed since it came from the factory, the
number 3 appears in the main display as shown in
Figure 4.31
. This is the default
setting.
2.
To change the setting, use the
0
through
3
buttons on the keypad to enter a new
option.
Note:
If an error is made, press the correct number. The new number
replaces the error.
3.
When the correct option number appears in the main display, press the [
ENTER]
button to save the selection.
4.
Press the [
CANCEL
] button to exit this menu code.
FIGURE 4.31 – AUDIO TONE
Sale $
Beeper
GGE
3
code
- 13
Sale $
idle
GGE
15
code
- 12
FIGURE 4.30 – IDLE TIMEOUT
Summary of Contents for CNG Spec. 100 Series
Page 3: ...Bennett CNG Spec 100 Series Operators Manual Bennett Limited Warranty i...
Page 4: ...Bennett CNG Spec 100 Series Operators Manual ii Page Intentionally Left Blank...
Page 46: ...Bennett CNG Spec 100 Series Operators Manual Programming 40 Page Intentionally Left Blank...
Page 56: ...Bennett CNG Spec 100 Series Operators Manual Diagnostics 50 Page Intentionally Left Blank...