Bennett CNG Spec. 100 Series Operators Manual
Programming
33
MENU CODE 28 – HOW TO SET ROUNDING OR TRUNCATING THE SALE AM OUNT
Menu Code 28 allows the manager or operator to set the dispenser for rounding or truncating the sale amount. The rounding option is
set as the default.
Note
: In order to guarantee that the sale display cross-multiplies properly for Weights & Measures, round the Sale
Amount.
0 - Truncating the Sale Amount
1 – (Default) Rounding the Sale Amount
TO SELECT A DIFFEREN T OPTION IN MENU CODE 28, FOLLOW THIS PROCEDURE:
1.
Press the number
2
and
8
, then the [
MODE
]
button on the keypad. The PPM display
shows the dispenser is in Menu Code 28. If the dispenser has not been programmed
since it came from the factory, the number 1 appears in the main display. This is the
default setting as shown in
Figure 4.48
.
2.
To change the setting, use
0
or
1
button on the keypad to enter a new option.
Note:
If an error is made, press the correct number. The new number will replace the error.
3.
When the correct option number appears in the main display, press the [
ENTER
]
button to save the selection.
4.
Press the [
CANCEL
] button to exit this Menu Code.
MENU CODE 29 – HOW TO SET THE RESETTABLE ELECTRONIC MASS TOT ALS
Menu Code 29 is used to reset the electronic resettable meter totals that accumulate in the dispenser every time a sale is completed. This
resetting feature is accessed through Menu Code 29. Refer to the
How to Operate
section,
How to Read Electronic Totals with the
Magnetic Reed Switch
. The totals in Menu Code 1 are not affected by this mode and will continue to accumulate totals until there is a
RAM memory clear.
TO SET THE MASS TOTALS ON THE DISPENSER, FOLLOW THIS PROCEDU RE:
1.
Press the number
2
and
9
, then the [
MODE
] button on the keypad. The top left price
display shows the dispenser is in Menu Code 29. The first digit shows that it is
displaying the totals for the mass of Product 1. The right price display shows that it
is displaying side 1. The display would appear as in
Figure 4.49
.
2.
To reset the totals, select the desired total and press the
0
button.
Figure 4.50
WARNING: THIS STEP ZEROS ALL THE MASS TOTALS IN THIS MENU CODE.
MAKE SURE ALL METER TOTALS ARE RECORDED BEFORE
PROCEEDING WITH THE NEXT STEP. DATA CANNOT BE
RETRIEVED.
3.
Press the [
CANCEL
] button to exit this menu code.
FIGURE 4.48 – ROUNDING SALE AMOUNT1
Sale $
round
GGE
1
code
- 28
FIGURE 4.49– TOTAL MASS AMOUNT
Sale $
1234
GGE
567.890
7.29
--1
Sale $
2345
GGE
678.901
02.29
--1
FIGURE 4.50 – RESET MASS TOTAL
Summary of Contents for CNG Spec. 100 Series
Page 3: ...Bennett CNG Spec 100 Series Operators Manual Bennett Limited Warranty i...
Page 4: ...Bennett CNG Spec 100 Series Operators Manual ii Page Intentionally Left Blank...
Page 46: ...Bennett CNG Spec 100 Series Operators Manual Programming 40 Page Intentionally Left Blank...
Page 56: ...Bennett CNG Spec 100 Series Operators Manual Diagnostics 50 Page Intentionally Left Blank...