Bennett CNG Spec. 100 Series Operators Manual
Operation
10
TO ENABLE THE DISPEN SER FOR PROGRAMMING, FOLLOW THIS PROCEDURE:
1.
Remove the keyboard from the zip plastic bag located on the inside of the electronic enclosure.
2.
Locate the J4 connector on the (blue) product select/auxiliary backlight board, which is located
on the backside of side 1 electronic door. The plug connector (J4 Connector) is located on the
right side of the product select/auxiliary backlight board.
3.
Plug the manager’s keyboard into the product select/auxiliary backlight board connector
observing the plug polarity. When the Manager’s Keypad is properly connected, the dispenser
will automatically enter the managers programming mode. The dispenser’s display will read
Enter
side 1
.
4.
Press the
Enter
button to enter Manager’s Mode. Programming can now be started and each
menu code can be programmed individually.
5.
Buttons
0
through
9
on the manager’s keypad shown in
Figure 18
are used to select the desired
menu code option. Press the
[MODE]
button on the keypad to enter a code.
Note
: Refer to the
Programming
section for more information.
6.
When the programming session is complete, remove the keypad from the connector, and
return the keypad to the bag for future programming sessions. When the Manager’s Keypad is
removed from the receptacle, the dispenser will automatically enter the operating mode.
MENU CODE 1 – HOW TO READ ELECTRONIC TOTALS
Menu Code 1 allows the manager to read the electronic non-resettable hose totals that accumulate in the dispenser for money, mass,
number of sales, and number of price changes.
Note:
For instructions on operator / attendant access to electronic totals, see
How to
Read Electronic Totals with the Magnetic Reed Switch
.
Press the
Up-Arrow
(
↑
) to move through product x totals (money, mass, sale/price counters)
Press
ENTER
to move from product x to product y.
TO READ THE MONEY TO TALS ON THE DISPENSE R, FOLLOW THIS PROCE DURE:
1.
Press the number
1
button and then the
[MODE
] button on the Manager’s Keypad. The
main display shows the total money amount. For example, if the total money amount
for the dispenser is $1,234,567.89 as shown in
Figure 3.4
. The PPM display reads
P1 1.1
for Product 1, Money Total, and Menu Code 1.
2.
Press the [
ENTER]
button to read the money totals for the second product if
applicable. The PPM display reads
P2 1.1
for Product 2, Money Total, and Menu Code
1.
Pressing the
Up-Arrow
(
↑
) button moves to viewing the product 1 volume total
(e.g. P12.1).
Pressing the
Up-Arrow
(
↑
) button also moves to viewing the sales counters
(e.g. P13.1).
Pressing the [
ENTER]
button at any time, switches to the same total for product
2 (e.g. P21.1, P22.1, and P23.1).
3.
Press the [
CANCEL
] button to exit this menu.
TO READ THE MASS TOT ALS ON THE DISPENSER , FOLLOW THIS PROCED URE:
1.
Press the
Up-Arrow
(↑) button
.
The money and mass displays indicates mass totals.
For example, see
Figure 3.5
if the total mass amount for the dispenser is 234,567.890
gallons. These totals are accumulative and cannot be changed. The dispenser can
carry the mass amount to three decimal places for gallons and two decimal places for
liters.
2.
Press the [
ENTER
] button on the keypad to view remaining hose positions.
Pressing the
Up-Arrow
(↑) button moves to return to money totals.
Pressing the
Up-Arrow
(↑) button also moves to viewing the sales counters
(e.g. P13.1).
Press the
Enter
button at any times, switches to the same total for product 2
(e.g. P21.1, P22.1, P23.1).
3.
Press the [
CANCEL
] button to exit this menu.
FIGURE 3.4 - MONEY TOTALS
FIGURE 3.5 - MASS TOTALS
Sale $
123
GGE
4567.89
P11.1
Sale $
234
GGE
5678.90
P21.1
FIGURE 3.3 – MANAGER’S KEYPAD
Summary of Contents for CNG Spec. 100 Series
Page 3: ...Bennett CNG Spec 100 Series Operators Manual Bennett Limited Warranty i...
Page 4: ...Bennett CNG Spec 100 Series Operators Manual ii Page Intentionally Left Blank...
Page 46: ...Bennett CNG Spec 100 Series Operators Manual Programming 40 Page Intentionally Left Blank...
Page 56: ...Bennett CNG Spec 100 Series Operators Manual Diagnostics 50 Page Intentionally Left Blank...