5 Configuration and startup
5.4 Configuration of the LioN-P
EtherNet/IP modules
MSB
LSB
Bit
15 14 13 12 11 10 9 8
7 6 5 4 3 2 1 0
Word 1
Process data direction port X1, channel A (pin 4), static value 1
Word 2
Process data direction port X1, channel B (pin 2), static value 1
:
:
Word 15 Process data direction port X8, channel A (pin 4), static value 1
Word 16 Process data direction port X8, channel B (pin 2), static value 1
Table 36: Process data direction for the 16DIO module with DI profiles
MSB
LSB
Bit
15 14 13 12 11 10 9 8
7 6 5 4 3 2 1 0
Word 33 Process data direction port X1, channel A (pin 4), static value 2
Word 34 Process data direction port X1, channel B (pin 2), static value 2
:
:
Word 47 Process data direction port X8, channel A (pin 4), static value 2
Word 48 Process data direction port X8, channel B (pin 2), static value 2
Table 37: Process data direction for the 16DIO module with DO profiles
MSB
LSB
Bit
15 14 13 12 11 10 9 8
7 6 5 4 3 2 1 0
Word 33 Process data direction port X1, channel A (pin 4), value range 1...2, default value 1
Word 34 Process data direction port X1, channel B (pin 2), value range 1...2, default value 1
:
:
Word 47 Process data direction port X8, channel A (pin 4), value range 1...2, default value 2
Word 48 Process data direction port X8, channel B (pin 2), value range 1...2, default value 2
Table 38: Process data direction for the 16DIO module with 8DI/8DO
profiles
Manual LioN-P EtherNet/IP
Version 2.0 11/2017
49