5.4 Configuration of the LioN-P
EtherNet/IP modules
5 Configuration and startup
MSB
LSB
Bit
15 14 13 12 11 10 9 8
7 6 5 4 3 2 1 0
Word 49 IO mapping port X1, channel A (pin 4), value range 0...7, 255, default value 0
Word 50 IO mapping port X1, channel B (pin 2), value range 0...7, 255, default value 1
:
:
Word 63 IO mapping port X8, channel A (pin 4), value range 0...7, 255, default value 6
Word 64 IO mapping port X8, channel B (pin 2), value range 0...7, 255, default value 7
Table 43: IO mapping on the 16DIO module with 8DI/8DO profiles
5.4.3 Configuration in RSLogix 5000
The configuration and start-up of the LioN-P modules described on the
following pages refers to the RSLogix 5000 software from Rockwell
Automation. If you are using a control system from another provider, please
consider the related documentation.
1.
Create a new project in RSLogix 5000.
2.
Select the correct controller.
3.
Add the correct EtherNet/IP communication interface to your backplane in
the
Controller Organizer
under
I/O Configuration
.
4.
Select a communication path with the control system with
Select Recent
Communications Path
.
5.
Install the EDS files of the LioN-P modules in RSLogix 5000 through the
tools main menu using the
EDS Hardware Installation Tool
.
6.
Add a LioN-P module to your EtherNet/IP communication interface with a
right click and menu item
New Module...
.
Manual LioN-P EtherNet/IP
Version 2.0 11/2017