5.4 Configuration of the LioN-P
EtherNet/IP modules
5 Configuration and startup
5.4.1.1 16DIO modules: 0980 ESL 310-xxx / 0980 ESL 390-xxx
Link
Connection type
Diagnostics Assembly ID
Length
Output: 100
2 byte
Input: 101
7 byte
16 DI/DO + DIA
Exclusive Owner
Yes
Configuration: 110
130 byte
Output: 100
2 byte
Input: 102
3 byte
16 DI/DO
Exclusive Owner
No
Configuration: 110
130 byte
Output: 193
0 byte
Input: 101
7 byte
16 DI/DO + DIA
Input Only
Yes
Configuration: 110
130 byte
Output: 193
0 byte
Input: 102
3 byte
16 DI/DO
Input Only
No
Configuration: 110
130 byte
Table 7: 16 DI/DO profiles
Link
Connection type
Diagnostics Assembly ID
Length
Output: 103
1 byte
Input: 104
6 byte
8 DI/DO + DIA
Exclusive Owner
Yes
Configuration: 111
130 byte
Output: 103
1 byte
Input: 105
2 byte
8 DI/DO
Exclusive Owner
No
Configuration: 111
130 byte
Manual LioN-P EtherNet/IP
Version 2.0 11/2017