5.4 Configuration of the LioN-P
EtherNet/IP modules
5 Configuration and startup
Link
Connection type
Diagnostics Assembly ID
Length
Output: 192
0 byte
Input: 108
8 byte
Generic 16 DI + DIA
(Even DI/DO-bytes)
Listen Only
Yes
Configuration: n/a
0 byte
Table 15: Even number of DI/DO-bytes profiles
5.4.1.2 16DIO DCU modules: 0980 ESL 390-121-DCU1
Link
Connection type
Diagnostics Assembly ID
Length
Output: 100
20 byte
Input: 101
25 byte
16 DI/DO + DIA + DCU Exclusive Owner
Yes
Configuration: 110
130 byte
Output: 100
20 byte
Input: 102
21 byte
16 DI/DO + DCU
Exclusive Owner
No
Configuration: 110
130 byte
Output: 193
0 byte
Input: 101
25 byte
16 DI/DO + DIA + DCU Input Only
Yes
Configuration: 110
130 byte
Output: 193
0 byte
Input: 102
21 byte
16 DI/DO + DCU
Input Only
No
Configuration: 110
130 byte
Table 16: 16 DI/DO DCU profiles
Link
Connection type
Diagnostics Assembly ID
Length
Output: 103
19 byte
Input: 104
24 byte
8 DI/DO + DIA + DCU
Exclusive Owner
Yes
Configuration: 111
130 byte
Output: 103
19 byte
Input: 105
20 byte
8 DI/DO + DCU
Exclusive Owner
No
Configuration: 111
130 byte
Manual LioN-P EtherNet/IP
Version 2.0 11/2017
34