BELARUS-
1523/1523В
/1523.3
/1523В.3
Drive Controls and Instrumentation
45
Safety Fuse Blocks
Two blocks of electric circuit safety fuses
БП
-
1 and БП
-2 are mounted under the
dashboard.
To gain access to the safety fuses, turn
out the screw (A) and remove the cover
(B). Eleven safety primary fuses protect
the following electric circuits from over-
load:
БП
-1:
1 – instrumentation supply (1
5 А);
2 – turn-signal light interrupter (7.5
А);
3 – right-hand headlight low beam (7.5
А);
4 – left-hand headlight low beam (7.5
А);
5 – right-hand marker lights and
dashboard backlight (15
А);
6 – left-hand marker lights (7.5
А).
БП
-2:
1 – headlight high beam (25
А);
2 – horn
(15 А);
3 – fault signalling light
(15 А)
;
4 – fault signalling light
(15 А);
5 – windscreen wiper and washer (15
А);
6 – stop light
(15 А).
WARNING!
To prevent the tractor elec-
tric wiring from burning,
NEVER
use
the fuses with ratings exceeding those
specified above. If a safety fuse gets
blown out frequently, find out the cause
and rectify the fault before fitting a new
one.