1523.5-0000010 OM
40
lubrication system is displayed in the upper right corner, cooling fluid temperature - in the
lower right corner, current fuel flow per hour - in the lower left corner. When the three-
segment imaging is indicated, the displayed parameters in the lower left corner are chosen
with button 1. To exit the mode of choosing between the displayed parameters in the up-
per right corner it is required to press button 5 after activation of the button panel 6. After
that the parameters are chosen between with buttons 1 and 2.
After calling up button panel 6, a four-segment imaging of parameters on screen 7 is acti-
vated with button 2. After the first pressing button 2, four parameters are displayed in the
digital mode on the screen:
- in the upper left corner – engine speed;
- in the upper right corner – coolant temperature;
- in the lower left corner – on-board voltage;
- in the lower right corner – oil pressure in the lubrication system.
When pressing button 2 for the second and third time, four parameters are displayed on
the screen in an analog form.
Using the mode of choosing between the displayed parameters, the customer can activate
if necessary displaying of various engine parameters on the screen according to table 2.7.
The mode of parameter choosing is activated after calling up the button panel with short-
time pressing button 5. Successive pressing button 1 changes the parameters displayed in
the upper left corner, pressing button 2 changes the parameters in the upper right corner,
button 3 – in the lower left corner, button 4 – in the lower right corner. The parameter
choosing mode is exited with short-time pressing button 5.
After calling up the button panel by pressing button 3, graphical displaying of parameters
in the course of time is activated (functions as a parameter analogue recorder).
The required parameters are chosen with a successive pressing button 3 according to ta-
ble 2.7.
A temporary net can be adjusted in a configuration menu from 2, 10 or 30 min. to 1, 2, 4 or
8 hours. To enter the configuration menu it is necessary to press button 5 and hold it
pressed for more than 3 sec. Also it is possible to choose metric and British units of meas-
urement in this menu, among available languages it is possible to choose English, Span-
ish, Swedish, French, German, Italian, Dutch, Portuguese and Russian.
ATTENTION: ONLY DEALERS ARE AUTHORIZED TO CHANGE SETTINGS OF THE
CONFIGURATION MENU!
When errors (faults) are detected during the operation, the monitor produces a sound sig-
nal and a rhombic flashing window with an exclamation mark appears on the screen.
After calling up the button panel, a list of active errors (faults) is invoked with button 4.
Moving over the list is carried out with buttons 1 and 2.
To exit displaying of the lift of active errors, it is necessary to confirm the reception of all
errors by pressing button 3. After the errors stop appearing on the display, they are auto-
matically deleted from the list.