Neon Strip Kit Installation and Electrical Connections
6) In a case where the neon strip extends beyond the existing hole pattern, clip the 2
” (5.08
mm) alunimum extrusion to the bottom of the neon strip a
t least 1/4” (6.35 mm) above
the plastic ends as shown below.
7) Mark the location of the aluminum channel. Remove the neon strip, drill the two holes
and then screw the extrusion into place.
8) Once all of the aluminum extrusions have been properly installed, remove the neon
strips from the channel. DO NOT REMOVE THE NEON STRIPS FROM THE
PENDANT. Apply drops of silicone adhesive to the inside corners of the aluminum
extrusions spaced one foot apart. See example below.
9) Snap the neon strips back into place.
Note:
Above image shows the Oval Pendant
10) Run the electrical wires that are on the ends of the neon strips through the front of the
pendant and into the electrical enclosure assembly. Pull the wires into the electrical
enclosure far enough where the neon strips are butted up all the way on the front of the
pendant and then tighten the cord grips. See image below.
11) Run the field connection wire from the supplied transformer through the grommet that is
on the top of the front cover and then into the top of the electrical box. Refer to the
wiring images for proper electrical hookups.
1/4”
(6.35 mm)
minimum
Apply
silicone
adhesive
here