CHAMELEON® ARCH SERIES
46
Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681
1MANUL526
Installation
Additional Options: Single K-Nozzle Manifolds
Single K-Nozzle Manifold Installation
1) Locate the box that the K-Nozzle components shipped in and confirm that all of the
pieces are there and also that there is no damage to any of the components.
2) Remove the two foam tube assemblies, the driver side spray manifold assembly and the
passenger side spray manifold assembly. The side spray manifolds are labeled with a
tag.
3) Apply Teflon
™ tape and liquid Teflon™ to the threads on the ends of both side spray
manifolds.
4) Mount a foam tube assembly to the end of each manifold. When you tighten the foam
tube assemblies to the manifolds, make sure that the elbow fittings (shown in dotted
ovals below) face away from the center of the bay.
After
Before
Apply Teflon™ tape and
liquid Teflon™ here
Apply Teflon™ tape and
liquid Tef
lon™ here