EL72x1-0010-MDP742 - Object description and parameterization
Index 8008 FB OCT Settings
Index (hex) Name
Meaning
Data type
Flags
Default
8008:0
FB OCT Settings
Maximum subindex
UINT8
RO
0x00 (0
dec
)
8008:01
Enable autoconfig
Configuration takes place automatically after the read-
ing of the electronic type plate
(see
Automatic scanning of the electronic type plates
[
}
112]
)
BOOLEAN
RW
0x00 (0
dec
)
8008:02
Reconfig identical mo-
tor
When replacing identical motors, reconfiguration takes
place automatically after reading the electronic type
plate.
Enable autoconfig
must be activated.
(see
Automatic scanning of the electronic type plates
[
}
112]
)
BOOLEAN
RW
0x00 (0
dec
)
8008:03
Reconfig non-identical
motor
When replacing non-identical motors, reconfiguration
takes place automatically after reading the electronic
type plate.
Enable autoconfig
must be activated.
(see
Automatic scanning of the electronic type plates
[
}
112]
)
BOOLEAN
RW
0x00 (0
dec
)
Index 8010 DRV Amplifier Settings
Index (hex) Name
Meaning
Data type
Flags
Default
8010:0
DRV Amplifier Settings Maximum subindex
UINT8
RO
0x42 (66
dec
)
8010:01
Enable TxPDOToggle Show TxPDO toggle in status word (bit 10)
BOOLEAN
RW
0x00 (0
dec
)
8010:11
Device type
1: Servo drive (cannot be changed)
UINT32
RW
0x00000001
(1
dec
)
8010:12*
Current loop integral
time
Integral component of current controller
Unit
: 0.1 ms
This value is affected by automatic scanning.
(see
Automatic scanning of the electronic type plates
[
}
112]
)
UINT16
RW
0x000A (10
dec
)
8010:13*
Current loop propor-
tional gain
Proportional component of current controller
Unit
: 0.1 V/A
This value is affected by automatic scanning.
(see
Automatic scanning of the electronic type plates
[
}
112]
)
UINT16
RW
0x0064
(100
dec
)
8010:14
Velocity loop integral
time
Integral component of velocity controller
Unit: 0.1 ms
UINT32
RW
0x00000032
(50
dec
)
8010:15
Velocity loop propor-
tional gain
Proportional component of velocity controller
Unit
: mA / (rad/s)
UINT32
RW
0x00000096
(150
dec
)
8010:17
Position loop propor-
tional gain
Proportional component position controller
Unit
: (rad/s) / rad
UINT32
RW
0x0000000A
(10
dec
)
8010:19
Nominal DC link volt-
age
Nominal DC link voltage
Unit
: mV
UINT32
RW
0x0000BB80
(48000
dec
)
8010:1A
Min DC link voltage
Minimum DC link voltage
Unit
: mV
UINT32
RW
0x00001A90
(6800
dec
)
8010:1B
Max DC link voltage
Maximum DC link voltage
Unit
: mV
UINT32
RW
0x0000EA60
(60000
dec
)
8010:29
Amplifier I2T warn
level
I²T model warning threshold
Unit
: %
UINT8
RW
0x50 (80
dec
)
8010:2A
Amplifier I2T error
level
I²T model error threshold
Unit
: %
UINT8
RW
0x69 (105
dec
)
8010:2B
Amplifier Temperature
warn level
Overtemperature warning threshold
Unit
: 0.1 °C
UINT16
RW
0x0320
(800
dec
)
8010:2C
Amplifier Temperature
error level
Overtemperature error threshold
Unit
: 0.1 °C
UINT16
RW
0x03E8
(1000
dec
)
8010:31
Velocity limitation
Velocity limitation
Unit
: rpm
UINT32
RW
0x00040000
(262144
dec
)
8010:32
Short-Circuit Brake du-
ration max
Max. duration of armature short circuit brake
Unit
: ms
UINT16
RW
0x03E8
(1000
dec
)
8010:33
Stand still window
Standstill window
Unit
: rpm
UINT16
RW
0x0000 (0
dec
)
*) see index 9009 FB OCT Nameplate
EL72x1-0010
166
Version: 2.0
Summary of Contents for EL7201-0010
Page 2: ......
Page 47: ...Commissioning Fig 42 TCP IP setting for the Ethernet port EL72x1 0010 47 Version 2 0 ...
Page 57: ...Commissioning Fig 61 EtherCAT terminal in the TwinCAT tree EL72x1 0010 57 Version 2 0 ...
Page 119: ...Commissioning Fig 148 Touch Probe inputs EL72x1 0010 119 Version 2 0 ...
Page 138: ...Commissioning Fig 168 Process Data tab SM2 EL72x1 0010 default EL72x1 0010 138 Version 2 0 ...
Page 142: ...Commissioning Fig 171 Process Data tab SM2 EL72x1 0010 default EL72x1 0010 142 Version 2 0 ...