Commissioning
Fig. 159:
Selecting a predefined PDO assignment
• Activate the configuration (Ctrl+Shift+F4).
• Run through the State Machine of the terminal. There are two ways to do this:
◦ If you use the TwinCAT NC.
The State Machine is run through automatically by the NC. You can enable the axis in the
On-
line
tab of the axis.
Set all tick marks and set
Override
to 100% (see Fig.
Set enables
). The axis can then be
moved.
EL72x1-0010
130
Version: 2.0