98
If you are connecting to another BayTech product (such as Tran-x),
please refer to
Appendix A.3
for the recommended cable pinouts.
A.2.2
EIA-422 XON/XOFF
HANDSHAKING
When connecting an EIA-422 device to the PS-4C or PS-4E using
XON/XOFF handshaking, the cable required to connect the two
devices must have TX+ wired to RX+ (and vice versa) and TX-
wired to RX- (and vice versa). Please see
Figure 14
below.
PS-4C or PS-4E Equipment
(EIA-422) Connections
RJ-45
1
2
3 TX+ RX+
4 TX- RX-
5 RX- TX-
6 RX+ TX+
7
8
Figure 14
: EIA-422 Connection using XON/XOFF Handshaking
If you are connecting a device which is not another BayTech
product, you must refer to the operator's manual for your
equipment to determine which pins are defined as TX+, TX-, RX+,
and RX-.
If you are connecting to another BayTech product (such as Tran-x),
please refer to
Appendix A.3
for the recommended cable pinout.
Summary of Contents for LASERSHARE PS-MIO
Page 100: ...94 ...
Page 101: ......
Page 114: ...108 APPENDIX E MECHANICAL LAYOUTS E 1 PS 4A PS 4C AND PS 4E ...
Page 115: ...E 2 PS MIO ...
Page 116: ...110 E 3 PS 4A SHIELDED TWISTED PAIR JUMPER LOCATION ...
Page 117: ...E 4 PS 4C SHIELDED TWISTED PAIR JUMPER LOCATION ...
Page 118: ...112 E 5 PS 4E SHIELDED TWISTED PAIR JUMPER LOCATION ...
Page 132: ... ...
Page 133: ... ...