X27 Main circulating pump
X28
T dhw 1: temperature sensor at the top of the domestic hot water
tank
T dhw 2: temperature sensor at the bottom of the domestic hot
water tank
Outdoor temperature sensor
Optional SCB-04 PCB terminal block
X1 Power supply for the pump/Three-way valve/Safety valve input
X2 PWM pump
X6 230 V power supply
X3
R-Bus: Room temperature sensor, Mago thermostat, on/off
thermostat, modulating thermostat or OpenTherm thermostat
Tout: Outdoor temperature sensor
Tflow: Flow sensor
X8 CAN bus to the EHC–04 PCB
X9 Bus CAN
6.7.5
Accessing the PCBs and connection terminal block
1. Remove the front panel by pulling firmly upwards.
2. Remove the plate concealing the PCBs.
3. Pivot the PCB support for routing the cables and connecting certain
options.
Fig.48
MW-3000557-03
X8
X9
X3
X2
X1
FUSE
SW2
X6
Fig.49
MW-3000546-01
2
1
Fig.50
MW-3000597-02
3
6 Installation
48
AWHP-2 PBS-i
7706696 - v04 - 11102018