ADV parameter
Description of the ADV advanced parameters
Factory setting
EHC–04
HP079
Maximum offset applied on the dynamic cooling setpoint when a 0-10V humidity
sensor is used
Can be set from 0 to 15°C
5
HP086
Activation of hydraulic management mode for the configuration with a low-loss
header, or for a buffer tank connected as a low-loss header
0 =No
1 =Yes
0
HP087
Buffer tank hysteresis to start and stop heating
Can be set from 0 to 30 °C
6
HP091
Offset temperature of heating setpoint when photovoltaic function is activated
Can be set from 0 to 30 °C
0
HP092
Offset temperature of DHW setpoint when photovoltaic function is activated
Can be set from 0 to 30 °C
0
HP094
Start time of the low noise when function activated
Can be set from 00:00 to 23:59
Value accepted when HP058 = 1
22:00
HP095
Stop time of the low noise when function activated
Can be set from 00:00 to 23:59.
Value accepted when HP058 = 1
06:00
HP108
Activation time delays for the back-ups between stage 1 and stage 2 (electrical
back-up) in central heating mode
4
PP016
Maximum central heating pump speed (%)
Maximum pump speed in heating mode
Can be set from 20 to 100%
100%
PP018
Minimum central heating pump speed (%)
Minimum pump speed in heating mode
Can be set from 20 to 100%
30%
AD
Auto detect
available
CNF
Reset factory parameters
See the data plate
ADV
ADV advanced parameters
not available
9.3
Setting the parameters
9.3.1
Language selection
1. Access the User menu.
2. Select the HMI sub-menu.
3. Select the AP103 parameter corresponding to language selection by
pressing the or keys.
4. Confirm by pressing the
key.